  1.  
  2. SUBJECT:      Invalid channel semaphore state on NETWARE release ERROR
  3. DATE:         Jan. 24, 1990
  4. OS VERSION:   2.1x
  5.  
  6.  
  7. GENERAL 
  8. INFORMATION:  Error messages
  9.  
  10. PROBLEM:      Error message at the server:  INVALID CHANNEL SEMAPHORE 
  11.               STATE ON NETWARE RELEASE
  12.  
  13. SOLUTION:     We have seen this error several different times and in 
  14.               each case it involves a Future Domain VADD.  We contacted 
  15.               Future Domain, and they said that the version 2.02 fixes 
  16.               this problem.  The customer needs to upgrade the VADD.
  17.  
  18. COMMENTS 
  19. (Optional):   Customer needs to contact Future Domain with this error 
  20.               message and fix.  FAX number: 714-259-5210
  21.  
  22.   (XX)    This information has been verified.
  23.  
  24.  
  25. SUBJECT:      Mirroring Using Generic SCSI or Future Domain VADD
  26. DATE:         February 13, 1990
  27. OS VERSION:   2.15
  28. REVISION:     C
  29. SHELL 
  30. VERSION:      N/A
  31. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
  32.  
  33. GENERAL 
  34. INFORMATION:  DCB Generic SCSI: Disk process accesses the drive to 
  35.               determine the number of heads and cylinders, rather than
  36.               using a table like the rest of the options in DISKSET.  
  37.               If the information cannot be read, the message "ABEND: 
  38.               Error adding a Generic Scsi Drive" appears.  This 
  39.               message means that the OS, COMPSURF, VREPAIR, BACKUP, 
  40.               RESTORE, and so on, could not talk to the drive, which 
  41.               denotes a hardware problem.
  42.  
  43. PROBLEM:      On a system with mirrored 600 Meg drives, using the 
  44.               Generic SCSI option, a customer reported that he 
  45.               could not bring the system up after a bad drive was 
  46.               removed.  His problem was two-fold because in one 
  47.               case two DCBS were used and in the other case the 
  48.               Future Domain VADD was used.
  49.  
  50.               The Future Domain VADD is similar to the DCB 
  51.               "Generic SCSI" option in that it also determines 
  52.               the number of heads and cylinders from the drive.  
  53.               But, unlike the DCB, that is the ONLY way it can be 
  54.               set up.  Therefore if one drive is removed it attempts 
  55.               to communicate with the missing drive, fails, and
  56.               doesn't add the drive to its table.  When the system 
  57.               comes up under this condition, the message "ABEND: 
  58.               Invalid mirror definition table.  Run NETGEN" appears 
  59.               because the hardware only recognized one of the drives 
  60.               and the master system table has been configured with 
  61.               two.
  62.  
  63.               When using the DCB "Generic SCSI" option in the above 
  64.               situation, to avoid the error "ABEND: Error adding a 
  65.               Generic Scsi Drive," the tendency is to remove the 
  66.               "Generic SCSI" drive using DISKSET leaving no drives 
  67.               defined on one of the DCBS.  When the system comes up 
  68.               under this condition, the message "ABEND: Invalid 
  69.               mirror definition table.  Run NETGEN" appears because, 
  70.               again, the hardware only recognized one of the drives 
  71.               and the master system table has been configured with 
  72.               two.
  73.  
  74. SOLUTION:     With the Future Domain VADD there is no way around 
  75.               this other than replacing the missing drive.  The
  76.               drive doesn't have to be the same size as the drive 
  77.               removed, so long as there IS a drive there for the 
  78.               VADD to look at, the system will come up.
  79.  
  80.               With the DCB the workaround for this is to configure 
  81.               the DCB which has the bad drive defined for something 
  82.               other than "Generic SCSI" using DISKSET (i.e.  
  83.               "CDC WRENIII/EMBEDDED SCSI").  The message "Probem 
  84.               with drive XX: Error reading disk redirection
  85.               information on sector 14" (where XX is the logical 
  86.               drive number of the drive removed) will appear, but 
  87.               the system will come up. Likewise with COMPSURF, 
  88.               VREPAIR, and so on, the same message will appear.